- عنوان المناقصة
- Chilled Water System Chemical Treatment, Testing
- مرحلتان
- لا
- تاريخ الفتح
- 05/10/2026 12:16
- تاريخ الإغلاق
- 19/10/2026 12:19
- اسم المشتري
- أماني شلبي
- جهة الاتصال
- Butros Memari
- الهاتف
- 0505879937
- البريد الإلكتروني
- butros.memari@marsapropertie.ae
الوصف
اقرأ المزيد ▾ إخفاء ▴
Carry out initial water analysis and submit the existing water condition, proposed treatment method, and target acceptance ranges before dosing. • Provide an itemized proposal for the following chemicals, or technically approved equivalents: • Accepta 894 – Silicate-Based Corrosion Inhibitor. • Accepta 2337 – Nitrite-Based Corrosion Inhibitor. • Accepta 2886 – Microbiocide. • Submit chemical quantities and dosage calculations based on the confirmed system volume, initial analysis, and manufacturer’s recommendations, together with product datasheets and Safety Data Sheets. • Supply and dose the approved chemicals and circulate the treated water throughout the complete network and connected equipment. • Include 20 onsite water analysis visits, with a clearly defined monitoring period and visit schedule. • Include corrective chemical dosing during the agreed treatment and monitoring period, clearly stating the included quantities and any exclusions. • Monitor relevant water-quality parameters and chemical concentrations and submit a report after each visit. • Include final chemical analysis covering pH, conductivity, TDS, applicable inhibitor concentration, and dissolved iron, plus a final microbiological analysis for Total Bacterial Count (TBC), through an appropriately accredited laboratory. • Submit final laboratory results against the agreed acceptance ranges, treatment records, and recommendations for ongoing maintenance. • Identify missing isolation valves by unit, location, size, and quantity, and submit any required installation works as a separately priced item. • Clearly identify and separately price any necessary flushing, cleaning, or other preparatory works. • Provide a price breakdown for chemicals, dosing, monitoring visits, and laboratory testing, together with the execution schedule, required shutdowns, and exclusions. • Include all manpower, equipment, consumables, and safety measures required for the works.
ملاحظة للموردين
Include all manpower, equipment, consumables, and safety measures required for the works.
البنود
| البند | نوع البند | الوصف | الفئة | الوحدة | الكمية | مطلوب من | مطلوب حتى |
|---|---|---|---|---|---|---|---|
| 1 | Services | Chilled Water System Chemical Treatment, Testing | Chemicals | EA | 3 | 05/10/2026 | 19/10/2026 |